Cable Construction
Conductor : Annealed tinned copper to IS:10241 Part 3, uniformly bunched to form a circular shape
Insulation : Special core insulation HR-PVC 105° C
Primary Braid : Braided with glass fiber, 100% coverage
Secondary Braid : Braided with nylon fiber, 100% coverage
Lacquer : Overall construction is finally lacquered with nylon varnish
Properties
Max. Operating Voltage : 600V r.m.s.
Operating Temperature Range : -35°C to 105°C
Resistant to ester based fluids (hydraulic oil), acids, chemicals and solvents. The nylon and glass fibers are very good heat resistant materials.
Cable Design Parameters
Part Number |
Cable Size |
Conductor |
Radial Thickness |
Nylon Braidand Lacquer |
Overall Diameter of Cable |
DC
Conductor
Resistance
at 20°C
(Ω/km) |
Max. Current Rating (Amps.) – BS G 177 |
Nom.Cross
Sectional
Area
(Sq. mm) |
No. & Dia.of Wiresin (mm) |
Max.
Conductor
Diameter
(mm) |
Min.
Conductor
Diameter
(mm) |
Min.
PVC
Insulation |
Max.(mm) |
Min.(mm) |
Max.(mm) |
Min.(mm) |
120401050001 |
14 |
2.05 |
70/0.193 |
1.956 |
1.803 |
0.279 |
0.178 |
0.076 |
3.4 |
3 |
9.2 |
31 |
120401060001 |
12 |
3.22 |
110/0.191 |
2.438 |
2.286 |
0.279 |
0.178 |
0.076 |
3.8 |
3.5 |
5.85 |
43 |
120401070001 |
10 |
5.33 |
73/0.305 |
3.15 |
2.896 |
0.381 |
0.381 |
0.127 |
5 4. |
6 |
3.532 |
61 |
120401080001 |
8 |
8.76 |
120/0.305 |
3.242 |
3.937 |
0.381 |
0.381 |
0.127 |
6.3 |
5.9 |
2.154 |
87 |
120401090001 |
6 |
13.3 |
182/0.305 |
5.537 |
5.08 |
0.381 |
0.381 |
0.127 |
7.6 |
7.3 |
1.422 |
115 |
120401100001 |
4 |
21.5 |
294/0.305 |
6.909 |
6.452 |
0.483 |
0.381 |
0.127 |
9.3 |
8.8 |
0.877 |
160 |
120401110001 |
2 |
33.3 |
203/0.457 |
8.763 |
8.128 |
0.483 |
0.381 |
0.127 |
11.0 |
10.5 |
0.565 |
200 |
120401120001 |
1 |
40.7 |
248/0.457 |
9.754 |
9.119 |
0.559 |
0.381 |
0.127 |
12.2 |
11.7 |
0.463 |
220 |
120401130001 |
0 |
53.0 |
323/0.457 |
10.973 |
10.338 |
0.635 |
0.381 |
0.127 |
13.7 |
13.0 |
0.355 |
240 |
120401140001 |
00 |
68.3 |
416/0.457 |
12.446 |
11.684 |
0.686 |
0.381 |
0.127 |
15.4 |
14.6 |
0.276 |
270 |
Table I : Current Ratings for Multiple Circuits
Cable Size |
Nominal Cross Sectional Area (Sq. mm) |
Max. Current Rating (Amps) |
Single Cable |
3 – Bunched Cables |
7 – Bunched Cables |
12 – Bunched Cables |
14 |
2.05 |
31 |
24 |
17 |
12 |
12 |
3.22 |
43 |
30 |
22 |
15 |
10 |
5.33 |
61 |
47 |
36 |
25 |
8 |
8.76 |
87 |
65 |
49 |
36 |
6 |
13.3 |
115 |
87 |
65 |
– |
4 |
21.5 |
160 |
120 |
92 |
– |
2 |
33.3 |
200 |
155 |
120 |
– |
1 |
40.7 |
220 |
165 |
130 |
– |
0 |
53 |
240 |
185 |
168* |
– |
00 |
68.3 |
270 |
210/240* |
190** |
– |
* Denotes two cables only
** Denotes five cables only
Note :
1) The current rating mentioned in Table I are for bunched cables in free air at 40 °C.
2) Derating factors mentioned in Table II, shall to be used for higher ambient temperature.
Table II : Derating Factor of Uninyvin Cable for Different Ambient Temperature
Ambient temp. (°C) |
40 |
45 |
50 |
55 |
60 |
65 |
70 |
75 |
80 |
85 |
90 |
95 |
100 |
Derating factor |
1.0 |
0.96 |
0.92 |
0.88 |
0.83 |
0.78 |
0.75 |
0.73 |
0.68 |
0.62 |
0.53 |
0.48 |
0.3 |
Table III : Maximum 1 Minute Current Ratings for Multiple Circuits
Cable Size |
Nominal Cross Sectional Area (Sq. mm) |
Max. Current Rating (Amps) |
Single Cable |
3 – Bunched Cables |
7 – Bunched Cables |
12 – Bunched Cables |
14 |
2.05 |
50 |
47 |
43 |
42 |
12 |
3.22 |
72 |
67 |
62 |
60 |
10 |
5.33 |
110 |
107 |
104 |
101 |
8 |
8.76 |
173 |
165 |
159 |
153 |
6 |
13.3 |
250 |
236 |
230 |
– |
4 |
21.5 |
390 |
378 |
360 |
– |
2 |
33.3 |
545 |
530 |
520 |
– |
1 |
40.7 |
620 |
600 |
590 |
– |
0 |
53 |
705 |
690 |
680 |
– |
00 |
68.3 |
820 |
810 |
800 |
– |
Table IV : Test for Resistance to Fluids
Sr. No. |
Fluid Represented |
Test Fluids |
Temp. of Test |
Max. Change in Dia. % |
1 |
Aviation Turbine Fuel |
Kerosene |
20 ± 0.5 |
5 |
2 |
Fuel |
70% ISO Octane 30% Toluene by Vol. |
20 ± 0.5 |
5 |
3 |
Hydraulic |
Fluid 80% Ethylene Glycol Mono Ethyl Ether, 20% Castor Oil by Vol. |
50 ± 2 |
5 |
4 |
Ester Based Lubricating Oil |
Ester Based Hydraulic Fluid |
100 ± 2 |
5 |
Note: